- Weight
- 450 kg
- Dimensions
- 185 × 128 × 237 cm
- Colour
- Matte black
- Average electrical power
- 3 500 W (3.50 kW)
- Maximum electrical power
- 4 500 W (4.50 kW)
- Calculated energy
- 3.50 kWh at 3.50 kW over one hour
- EU power supply
- 400 V three-phase, 50 Hz. Max. 10 A operating current and 16 A protection.
- Windchill
- −70, −90 and −110 °C
- Cooling
- Air-cooled, integrated cooling unit. No separate water chiller.
- Exhaust air
- 400 mm diameter duct routed outside the building
- Heat rejection
- 11.50 kW at 20 °C cooling air
- Cooling airflow
- 2 000 m³/h
- Room conditions
- 15–23 °C, max. 35% relative humidity
- Room volume
- Starting requirement at least 25 m³. Smaller rooms require a specific ventilation and safety assessment.
- Noise at 3 m
- Approximately 70 dB(A)
- Clearance
- At least 150 cm at the cooling-unit side and 20 cm to the side wall, plus clear space for door opening and servicing.